Gas Monitoring System

Gaz Takip Sistemi
INTENDED AREAS OF USE FOR GTS50 SYSTEM;
  • IN SHIPYARDS, TANKERS,
  • IN NEW SHIPS CONSTRUCTIONS,
  • IN SHIPS IN REPAIR ZONES,
  • IN WORKS AND FACILITIES WHERE PERIODIC MEASUREMENTS ARE REQUIRED.
GTS50 SYSTEM

This system is designed to display regularly and periodically measured gas values and to allow intervention when necessary.

In the tankers which are repaired in the shipyard, samples are taken from the lower-middle and upper sections of the tank for a certain period of time, this period can be changed. (Tested for 130 seconds -No: 1 CT is approx. 200 meter – 130 seconds)

In the facilities; it is placed in a suitable place where the storage tanks are located, the measurement for multiple tanks can be periodically displayed during cleaning and maintenance.

In factories and facilities; any sensor can be changed and required gas values can be measured periodically from certain locations.

It is designed to take samples respectively from the upper, middle and lower sections of the tank.

Multi Rae Lite device is used in the testing phase and it is operated for 8-10 hours a day and tested in a tanker in a shipyard during repair for 15 days.

There are 50 ports of the system, 2 of which are used for testing purposes,

(Measurements can be made for up to 16 tanks. It is devised to have 3 ports per tank) number of ports can be increased.

When the system starts operating, it takes sample from Port No. 1 and continues to take samples in sequence until the system is turned off. (1, 2, 3, 4, …, 48, 1, 2, …)

THE SCREEN IS REFRESHED AT AN INTERVAL OF 60 SECONDS – DURATION CAN BE CHANGED, OLD DATA IS STORED FOR 2 MONTHS AND CAN BE DISPLAYED ON THE SCREEN WHEN DESIRED.

THE AMOUNT OF GAS IN THE TANKS WILL BE MEASURED IN SEQUENCE. THE MEASUREMENTS FOR INTENSIVELY USED TANKS CAN BE MADE AT AN INTERVAL OF 15-30 MINUTES.

The values can be viewed and controlled on a computer or on a phone typing the user name and password into the system.

Any tank can be measured individually.

When authorized personnel clicks on “Resume” button on control panel, values are started to be displayed for that tank and measurements are continued for the next tanks.

(In a normal cycle, if number 4 is pressed, tank No. 4 is measured, and then measurements are continued in ascending order. (4, 5, 6, 7, …, 48, 1, 2, …)

An audio and light alarm is triggered based on values at the end of the measurement.